Lutron Maestro Partial-On Dual Circuit Motion Sensor Switch, 6A Light, 120-277V, Single Pole, Ground or Neutral Required, MS-OPS6-DDV-BL, Black

$96.60

$64.40

Estimated Lead Time: 3-4 weeks

Product dimensions

  • Width:

    2.3 IN

  • Height:

    2.3 IN

  • Depth:

    4.5 IN

  • Weight:

    0.26 LBS

Combines two switches with an in-wall, passive infrared (PIR) occupancy or partial-on sensor. The sensor is intended for either control of two circuits or bi-level control of two circuits, as required by certain energy codes. Passive infrared sensor with exclusive Lutron XCT Technology for minor motion detection. 180 degree sensor field-of-view. Tamper-resistant PIR lens. Up to 30 ft x 30 ft (9 m x 9 m) [900 ft2 (81 m2)] major motion coverage and 20 ft x 20 ft (6 m x 6 m) [400 ft2 (36 m2)] minor motion coverage. Smart Ambient Light Detection (ALD) mode uses adaptive algorithm: Sensor learns the user's preferred light level over time. Adjustable timeout for each circuit (1, 5, 15, or 30 minutes). Sensitivity adjustment (high/low). Switches all lighting loads: incandescent, halogen, ELV, MLV, CFL, LED, magnetic fluorescent, electronic fluorescent.


  • Bi-level control of two circuits, as required by certain energy codes (e.g., ASHRAE)
  • Passive infrared sensor with exclusive Lutron XCT Technology for minor motion detection
  • 180 deg sensor field-of-view
  • Tamper-resistant PIR lens
  • Up to 30 ft x 30 ft (9 m x 9 m) [900 ft2 (81 m2)] major motion coverage and 20 ft x 20 ft (6 m x 6 m) [400 ft2 (36 m2)] minor motion coverage
  • Smart Ambient Light Detection (ALD) mode uses adaptive algorithm: Sensor learns the user's preferred light level over time
  • Occupancy version can be set to Auto-ON / Auto-OFF or Manual-ON / Auto-OFF
  • Adjustable timeout for each circuit (1, 5, 15, or 30 minutes)
  • Sensitivity adjustment (High/Low)
Supply Voltage 120 to 277
Type Occupancy sensor switch, dual-circuit, partial-on, single-pole
Sensor Yes
Standard UL, cUL, NOM, Title 20/24
Sensing Range, Maximum 900
Sensing Range, Minimum 400
Operating Temperature, Maximum 104 °F
Operating Temperature, Minimum 32 °F
Load 6 A@120 to 277 VAC lights/4.4 A@120 VAC fan
Enclosure Plastic
Environmental Conditions 0 to 90% humidity, non-condensing. Indoor use only.
Body Plastic
Application Lighting Control
Mounting Wallbox

Product dimensions

  • Width:

    2.3 IN

  • Height:

    2.3 IN

  • Depth:

    4.5 IN

  • Weight:

    0.26 LBS